By Dave Brennan
From 1 January 2027, the 68th edition of the IATA Dangerous Goods Regulations (DGR) will become the industry reference document used for the transport of dangerous goods by air.
The 68th edition introduces several changes affecting those involved in shipping pharmaceuticals, healthcare products, clinical trial materials and infectious substances.
These changes address the transport of blood and blood components, battery powered data loggers, medical devices carried by passengers and the classification of infectious substances. They also clarify how used medical devices containing lithium or sodium ion batteries are treated under the Regulations.
This article examines the changes, the background to their introduction and the practical implications for those involved in the air transport of medical and healthcare products.
Section 1: Applicability
1.2.7 Exceptions
Paragraph 1.2.7 sets out allowances for certain dangerous goods to be excepted from the provisions of the DGR.
The 2027 edition includes changes to two of these allowances, providing additional flexibility for the transport of medical and healthcare products.
Transport of blood and blood components
Subparagraph (a) permits the carriage of dangerous goods required to provide medical aid to a patient during flight or to preserve tissues or organs for transplantation.
This provision has been expanded to include dangerous goods required to preserve blood or blood components for transfusion.
The change was adopted to permit the carriage of a new type of battery powered refrigerator specifically designed to maintain blood at the required temperature during transport.
Importantly, this allowance remains subject to the prior approval of the airline or airlines involved.
Data loggers and cargo tracking devices
Subparagraph (i) permits data loggers and cargo tracking devices powered by lithium cells or batteries to be attached to, or placed within, packages, overpacks or unit load devices, subject to specified conditions.
This allowance has now been expanded to include devices powered by sodium ion cells or batteries.
The lithium ion cells or batteries must have a Watt hour rating not exceeding 20 Wh.
Shippers intending to use data loggers or cargo tracking devices should remember that, although the provisions of the DGR do not apply under this exception, the devices must still meet defined standards for electromagnetic radiation. This requires the prior approval of the airline or airlines on which the cargo will be carried.
This is a practical development for airlines, freight forwarders and ground service providers.
Data loggers and tracking devices are increasingly embedded in cargo movements, particularly those involving pharmaceuticals and healthcare products where shippers must be able to verify that products have remained within the required temperature range throughout transport.
The regulatory treatment of these devices needs to be reflected in acceptance checks, shipper guidance, booking systems and internal dangerous goods and operational procedures.
Section 2: Limitations
2.3 Dangerous Goods Carried by Passengers and Crew
The 2027 edition of the DGR introduces a clarification that may provide greater flexibility for medical professionals and healthcare providers carrying medical devices classified as dangerous goods, including those powered by lithium cells or batteries.
Paragraph 2.3.0.1 continues to limit the carriage of dangerous goods by passengers and crew to the items identified in paragraphs 2.3.2 to 2.3.5 for personal use.
A new note has been added to clarify the meaning of personal use.
In practical terms, personal use may extend beyond items owned or directly used by the passenger. It may also include items intended for use by others, such as gifts, portable electronic devices supplied by employers for work activities, or medical devices carried by device providers or medical professionals for imminent patient care.
However, personal use does not include items carried for sale or distribution.
This clarification is particularly relevant because passenger and crew provisions are frequently interpreted in real time during check in, security screening, boarding and cabin operations.
A clearer definition should support more consistent decisions about what constitutes personal use and what falls within commercial carriage, distribution or supply.
Section 3: Classification
Section 3 establishes the classification criteria applicable to dangerous goods.
The 2027 edition includes changes relating to the classification of infectious substances and the provisions governing the transport of used medical devices that may be contaminated with infectious substances.
3.6 Class 6: Toxic and Infectious Substances
3.6.2.2 Classification of Infectious Substances
At the United Nations Subcommittee, the expert from Canada, together with the representative from the World Health Organization (WHO), identified that recent emerging international health situations had resulted in requests to the WHO for guidance on transporting the pathogens involved, including their correct classification.
In response, amendments were proposed to provide a more flexible approach to the indicative list of Category A infectious substances.
The intention was to support a more effective risk based approach to classification while allowing the provisions to respond to emerging health situations.
It was also identified that the wording in Note 2 under paragraph 3.6.2.2.2.1(b), concerning new or emerging pathogens not listed in Table 3.6.D, Indicative Examples of Category A Infectious Substances, was regulatory in nature.
Consequently, it was proposed that this wording be moved from a note into the regulatory text.
The Subcommittee agreed to these changes and also revised the structure of the provisions governing the classification of Category A and Category B infectious substances.
The revised provisions now more clearly establish that infectious substances are divided into Category A and Category B.
Paragraph 3.6.2.2.2.1, including subparagraphs (a) and (b) and the notes beneath subparagraph (b), has been restructured into numbered paragraphs.
A new sentence has also been added to paragraph 3.6.2.2.2.1.4, formerly Note 2, providing guidance on emerging health situations:
“To address emerging health situations, more up-to-date information on the applicable categories can be obtained from human and animal health inter-governmental organizations and national authorities.”
This change recognises the importance of having access to current information when classifying infectious substances, particularly where new or emerging pathogens may not yet appear in the indicative examples.
3.6.2.2.3 Exceptions: Used Medical Devices
The medical device industry raised concerns with the United Nations Subcommittee regarding the exception for used medical devices under DGR 3.6.2.2.9.
The concern was that the exception did not adequately address medical devices containing, or packed with, lithium cells or batteries.
Under the previous provisions, used medical devices being transported for disinfection, cleaning, sterilisation, repair or equipment evaluation were required to be classified as UN 3373, Biological substance, Category B, where the devices also contained lithium batteries.
The industry considered that the appropriate classification should instead be determined by the applicable battery type, such as UN 3091 or UN 3481.
The Subcommittee agreed with this position and extended the change to include medical devices powered by sodium ion cells or batteries.
Changes to the exception
Paragraph 3.6.2.2.3.9.3(c) has been revised.
Previously, the exception from the Regulations was limited where a used medical device was contaminated with, or contained, other dangerous goods meeting another hazard class.
The revised provision permits used medical devices to contain, or be packed with, lithium cells or batteries or sodium ion cells or batteries.
New requirements for battery powered medical devices
A new paragraph, 3.6.2.2.3.9.4, has also been introduced.
Where used medical devices and equipment contain, or are packed with, lithium cells or batteries or sodium ion cells or batteries, the relevant entry in the Dangerous Goods List in Section 4.2 must be used.
All applicable provisions of the Regulations must also be met.
This change provides a clearer regulatory pathway for the transport of used medical devices containing batteries, while maintaining the applicable dangerous goods requirements for the battery type involved.
What These Changes Mean for Medical Logistics
The changes introduced in the 2027 IATA DGR have practical implications across several areas of medical and healthcare logistics.
For organisations transporting blood and blood components, the expanded exception provides additional flexibility for temperature controlled equipment, subject to airline approval.
For pharmaceutical and healthcare shipments using data loggers or cargo tracking devices, the inclusion of sodium ion batteries expands the types of devices that may qualify under the relevant exception. Shippers and logistics providers must nevertheless ensure that the specified conditions and airline approval requirements are satisfied.
Medical professionals and device providers may also benefit from the clarification of personal use provisions, particularly when carrying medical devices for imminent patient care.
For those involved in infectious substance transport, the revised classification provisions provide a clearer structure and recognise the need to consider current guidance when dealing with emerging pathogens.
Finally, the amendments concerning used medical devices provide greater clarity where equipment contains or is packed with lithium or sodium ion batteries.
Final Reflection
The 2027 changes demonstrate how dangerous goods regulations continue to evolve in response to developments in medical technology, healthcare logistics and emerging health situations.
While several amendments provide additional flexibility, they also reinforce the importance of understanding the conditions attached to each exception and the classification requirements that remain applicable.
For shippers, freight forwarders, airlines and healthcare organisations, reviewing these changes before the 68th edition takes effect will help ensure that operational procedures, acceptance processes and staff guidance remain aligned with the applicable requirements.